Standard Option |
1.1 | 1.2 | |||
| Label printer | MACH1 | MACH2 | |||
| Print head | |||||
| Printing method | Thermal transfer, direct thermal | ||||
| Printable resolution dpi | 203 | 300 | 203 | 300 | |
| Print width up to mm | 108 | 105.7 | 108 | 105.7 | |
| Print speed up to mm/s | 127 | 102 | 177 | 127 | |
| Material | |||||
| Paper, cardboard, plastics continuous material on a roll or fanfold |
![]() |
![]() |
|||
| Width Labels mm | 25 - 112 | ||||
| Liner continuous material mm |
25 –118 | ||||
| Label height at least mm | 4 | ||||
| up to mm | 1,727 | 762 | 1,727 | 762 | |
| Thickness mm | 0.06 - 0.2 | ||||
| Weight g/m2 | 60 - 160 | ||||
| Roll Outer diameter up to mm | 127 | ||||
| Core diameter mm | 25.4 - 38.1 | ||||
| Winding | Outside or inside | ||||
| Ribbon | |||||
| Ink side | Outside or inside | ||||
| Roll diameter up to mm | 68 | ||||
| Core diameter mm | 25.4 | ||||
| Variable length up to m | 300 | ||||
| Width mm | 25 –114 | ||||
| Printer size and weights | |||||
| Width x Height x Depth mm | 210 x 186 x 280 | ||||
| Weight kg | 2.7 | 3 | |||
| Label sensor with position indication | |||||
| Gap sensor | Fixed at center | ||||
| Reflective sensor from below | Adjustable | ||||
| Electronics | |||||
| Storage Flash MB | 16 | ||||
| SDRAM MB | 8 (4 MB for the application) |
||||
| Battery for current date/time, real-time clock | ![]() |
![]() |
|||
| Interfaces | |||||
| R232C | ![]() |
![]() |
|||
| USB for PC connection | ![]() |
![]() |
|||
| Ethernet | ![]() |
![]() |
|||
| USB Host | – | ![]() |
|||
| Operation panel | |||||
| Buttons Feed | ![]() |
![]() |
|||
| On/off | ![]() |
![]() |
|||
| Material sensor calibration | ![]() |
![]() |
|||
| LEDs Ready | ![]() |
– | |||
| Status | ![]() |
– | |||
| Colored TFT display with navigator pad | – | ![]() |
|||
| Operating data | |||||
| Power supply | 100 – 240 VAC, 50/60 Hz, PFC | ||||
| Power consumption up to W | 60 | ||||
| Temperature / humidity Operation: | +5 – 40°C/30 – 85 %, not condensing | ||||
| Storage: | -20 – 50°C/10 – 90 %, not condensing | ||||
| Transport: | -25 – 60°C/20 – 80 %, not condensing | ||||
| Approvals | CE, FCC, CCC, CB, UL, KCC | ||||